The nas probe (version 23.4.3.2 / 23.4.4) is crashing intermittently and failing to start properly, resulting in a growing alarm queue.
Log Indicators: The nas.log contains repeated SQLite execution errors:
System Error: Windows Event Viewer may show an application crash with ntdll.dll and exception code 0xc0000374:
Note: Attempting to resolve this by manually deleting existing database files does not restore service stability.
Non reproducible-issuee. This behavior is identified as a defect within the 23.4.4 release of the nas probe.
Follow these steps in order to resolve the crash and queue accumulation issues.
Before applying patches, attempt to reset the probe state:
nas and alarm_enrichment probes.nas probe version 23.4.4.alarm_enrichment and nas.If the cold start does not resolve the issue, you must upgrade to the 23.4.4.1 fix, which addresses both the SQLite execution errors and the alarm queue drainage failure.
nas.cfg file and the entire nas folder.nas folder. Warning: This action clears all current open and historic alarms stored locally in the probe directory.nas version 23.4.4.1 (or the latest available version).nas.cfg into the new nas directory.Monitor the nas.log to confirm that the errors cease and alarms are processed. If the issue persists, please open a support case with Broadcom DX UIM Support.
"nas: checkBatch(batch disabled): batchTime for... 956 operations performed".nas version 23.4.5 and later requires DX UIM 23.4 CU5 or newer.