vIDM cluster in failed state due to patching Aria Suite lifecycle 8.18 to patch 5 prior to patching vIDM with patch CSP-102092
search cancel

vIDM cluster in failed state due to patching Aria Suite lifecycle 8.18 to patch 5 prior to patching vIDM with patch CSP-102092

book

Article ID: 421788

calendar_today

Updated On:

Products

VCF Operations/Automation (formerly VMware Aria Suite)

Issue/Introduction

Incorrect patching order of Aria suite lifecycle and vIDM may encounter several unwanted issues, right order and prerequisites are described in KB article to follow: CSP-102092 Patch Instructions for VMware Identity Manager 3.3.7 and VMware Aria Suite Lifecycle 8.18.0 Patch 5

  • pgService fails to start with following error:
    pgpool [####] : [23-2] ####-##-## : pid ####: DETAIL: watchdog does not holds the quorum
    pgpool [####] : [24-1] ####-##-## : pid ####: FATAL: failed to create a backend connection
    pgpool [####] : [24-2] ####-##-## : pid ####: DETAIL: executing failover on backend
  • Remediate cluster does not resolve the health status of the vIDM cluster.

Environment

VMware Identity Manager 3.3.7

Cause

Any Day-2 operations performed from LCM after patching to patch 5 and prior to patching vIDM causes partial patching misconfigurations to vIDM cluster.

Resolution

Contact Broadcom support to validate issue and provide next steps to resolve the issue.

Creating and managing Broadcom support cases

Attachments

verify-cluster-prerequisites-v5.sh get_app