The SPM RTM_Test stopped running since last Spectrum upgrade
search cancel

The SPM RTM_Test stopped running since last Spectrum upgrade

book

Article ID: 420889

calendar_today

Updated On:

Products

Network Observability Spectrum

Issue/Introduction

We noticed the SRM stopped synchronizing the SPM events since last Spectrum upgrade, from version 24.3.5 to 25.4.1 on 11/20/2025.

mysql> select * from landscape\G

spm_sync_time: 2025-11-20 09:41:57

alarm_sync_time: 2025-11-27 15:01:15

event_sync_time: 2025-11-27 15:01:18

 

And the following error is thrown if we try to run any RTM_Test on demand:

SPC-OCC-10199: Error: Run Test

SPC-Occ-10183: The following error(s) occurred when attempting to run the selected test(s):

SPC-OCC-11635: The model does not exist on the SpectroSERVER.

 

By searching for the Model Type Handle = 0x4560000 we can find the RTM_Test models in the SSdb.

./show models | grep 0x4560000

Environment

DX NetOps Spectrum: 25.4.1

Resolution

Steps to resolve the issue:

a. Take an Online Backup of the SSdb.

b. Stop the primary SS and load the SSdb what was taken on step a.

c. Start the SpectroSERVER.