messages logs for the NE appliance./var/log/message.log in the NE appliance reports following error<131>1 2025-12-01T03:31:25+00:00 ServiceMesh-NE-I1 cgw 1459 - - [Err-Tasker] : cmd (/usr/local/sbin/conntrack -I -p esp -s 192.##.##.## -d 192.##.##.## -m 34 -t 600) failed </usr/local/sbin/conntrack -I -p esp -s 192.##.##.## -d 192.##.##.## -m 34 -t 600: exit status 1:conntrack v1.4.6 (conntrack-tools): Operation failed: Such conntrack exists, try -U to update><134>1 2025-12-01T03:31:25+00:00 ServiceMesh-NE-I1 cgw 1459 - - [Info-opsEvent] : new system event: SystemEvent[2025-12-01T03:31:24Z, 2025-12-01T03:31:24Z, 60002, critical, Memory usage is high, map[balloon:0] MB cache:14688256 free:97075200 total:3109163008 used:3012087808]]VMware HCX
The failure of NE appliance tunnels and other functions (such as extension, unextension, and enabling MON) is caused by a known memory leak in the ndd process of HCX 4.11.0. The leak results in high memory usage, leaving the NE appliance unable to allocate critical resources for these tasks.
Upgrade the HCX Manager and service mesh to 4.11.1 where this issue is resolved or the latest version ie 4.11.3