Service Mesh upgradation fails with below error.
The following messages can be found in the log file /common/logs/admin/app.log
DeployAppliance failed in state CONFIGURE_PORT_PROPERTIES. Error: Could not copy port properties while redeploying appliance ##-ServiceMesh-NE-I1-##-Redeploying. PKIX path building failed: sun.security.provider.certpath.SunCertPathBuilderException: unable to find valid certification path to requested target. Retry attempt: 0.
NSXService_SvcThread-890, Ent: HybridityAdmin, , TxId: #######-#######--#######--#######--#######-] ERROR c.v.v.h.s.n.NsxTInventorySyncJob- Failed to update NsxT Inventorycom.vmware.vchs.hybridity.adapters.https.UntrustedCertificateException: PKIX path building failed: sun.security.provider.certpath.SunCertPathBuilderException: unable to find valid certification path to requested target
[InterconnectService_SvcThread-475, IX:#######--#######--#######--#######--#######-, , TxId: #######-#######--#######--#######--#######] WARN c.v.v.h.s.i.DeployAppliance- DeployAppliance failed in state CONFIGURE_PORT_PROPERTIES. Error: Could not copy port properties while redeploying appliance AWS-ServiceMesh-NE-I1-eBb-Redeploying. PKIX path building failed: sun.security.provider.certpath.SunCertPathBuilderException: unable to find valid certification path to requested target. Retry attempt: 3.
[InterconnectService_SvcThread-484, Ent: HybridityAdmin, , TxId: #######-#######--#######--#######--#######] ERROR c.v.v.h.s.i.DeployAppliance- Retries exhausted for state CONFIGURE_PORT_PROPERTIES, exiting..[InterconnectService_SvcThread-485, SM:servicemesh-#######-#######--#######--#######--#######, IX:#######-#######--#######--#######--#######, TxId: #######-#######--#######--#######--#######] INFO c.v.v.h.s.i.ApplianceLifeCycleJob- Running in state: CHECK_DEPLOY[FailureDetectionService_EventListener, , , TxId: ] INFO c.v.v.h.f.FailedJobEventsListener- Received a Failed Job, jobType: InterconnectServiceJobs workflow type: DeployAppliance
[InterconnectService_SvcThread-485, SM:servicemesh-#######-#######--#######--#######--#######, IX:#######-#######--#######--#######--#######, TxId: #######-#######--#######--#######--#######] ERROR c.v.v.h.s.i.ApplianceLifeCycleJob- All DeployAppliance workflows have failed. Canceling operation and initiating rollback.
HCX
The NSX Certificate is mismatched. This can occur after updating the certificate on NSX.
Re-import the newly updated NSX Manager certificate.