Upgrading Service Mesh fails with "Error: Interconnect Service Workflow GenerateAndPostConfig failed. Error: Operation timedout in state POST_CONFIG_VIX"
search cancel

Upgrading Service Mesh fails with "Error: Interconnect Service Workflow GenerateAndPostConfig failed. Error: Operation timedout in state POST_CONFIG_VIX"

book

Article ID: 420653

calendar_today

Updated On:

Products

VMware HCX

Issue/Introduction

  • Unable to upgrade Service Mesh with Error: Operation timedout in state POST_CONFIG_VIX.
  • Redeploy/Force Redeploy also fails with same error.



  • The following error is observed in the HCX Manager /common/logs/admin/app.log

    2025-11-27 12:54:25.461 UTC [InterconnectService_SvcThread-587, Ent: HybridityAdmin, , TxId: ####-####-####-9aae918858da] ERROR c.v.v.h.a.postgresdb.PostgresAdapter- Error executing query ERROR: duplicate key value violates unique constraint "HbrToHostConnectionAlerts_applianceId_1_hostId_1_vCenterId_1"
      Detail: Key ((val ->> 'applianceId'::text), (val ->> 'hostId'::text), (val ->> 'vCenterId'::text))=(####-####-####-8f8e6ddfa19a, <IX-IP>, ) already exists.

    or

    2026-05-01 07:59:07.503 UTC [InterconnectService_SvcThread-82, J:c4045155, , TxId: ########-####-####-####-d9cf825bf310] ERROR c.v.v.h.s.i.InitiateApplianceOperation- InterconnectRedeploy workflow failed with error Redeploy of Interconnect Appliance failed. Interconnect Service Workflow InterconnectRedeploy failed.
    Error:  Deploy and Configuration of Interconnect Appliances Failed. Interconnect Service Workflow DeployAppliance failed. Error: Unknown.

Environment

VMware HCX

Cause

This is failing due to some stale entries for the appliance in HCX DB.

Resolution

If you believe you have encountered this issue, please open a support case with Broadcom Support and refer to this KB article.
For more information, see Creating and managing Broadcom support cases.

Please collect HCX Logs [Select All] and upload to SR. Refer Gather Technical Support Logs


WORKAROUND:
If no migrations are currently in progress, you may deploy a new Service Mesh instance with the same service appliance type. Please ensure that the new appliance selects an IP address different from the one referenced in the error log.

If the appliance is a Network Extender you can remove the affected instance by reducing the number of NEs in the Service Mesh configuration: this will clean up the stale records and then allow increasing their number back to the original value in the Service Mesh, deploying a new replacement NE in the current version of HCX.

Additional Information

HCX Service Mesh deployment fails with "Error: Operation timedout in state POST_CONFIG_VIX"" when static routes are configured via the HCX UI

Service mesh upgrade or deployment task fails