Several VMs frequently become unresponsive and the Web Console cannot be launched.
In vmware.log, the GuestRpcSendTimedOut message to toolbox is continuously being recorded.
YYYY-MM-DDTXX:XX:XX.XXX In(05) vmx - GuestRpcSendTimedOut: message to toolbox timed out.YYYY-MM-DDTXX:XX:XX.XXX In(05) vmx - Tools: [AppStatus] Last heartbeat value 326955 (last received 9s ago)YYYY-MM-DDTXX:XX:XX.XXX In(05) vmx - TOOLS: appName=toolbox, oldStatus=1, status=2, guestInitiated=0.YYYY-MM-DDTXX:XX:XX.XXX In(05) vmx - GuestRpcSendTimedOut: message to toolbox timed out.YYYY-MM-DDTXX:XX:XX.XXX In(05) vmx - GuestRpc: app toolbox's second ping timeout; assuming app is downYYYY-MM-DDTXX:XX:XX.XXX In(05) vmx - Tools: [AppStatus] Last heartbeat value 326955 (last received 29s ago)YYYY-MM-DDTXX:XX:XX.XXX In(05) vmx - TOOLS: appName=toolbox, oldStatus=2, status=0, guestInitiated=0.
At the same time, there are instances of storage errors and performance degradation in vmkernel.log. This datastore is where the VM located.
YYYY-MM-DDTXX:XX:XX.XXX In(182) vmkernel: cpu97:2098613)ScsiDeviceIO: 4605: Cmd(0x45da2de3c100) 0x8a, cmdId.initiator=0x430f2f017240 CmdSN 0x3ff from world 25436963 to dev "naa.xxxxxxxxxxxxxxxxxx" failed H:0x8 D:0x0 P:0x0 Cancelled from driver layer YYYY-MM-DDTXX:XX:XX.XXX In(182) vmkernel: cpu52:2097363)NMP: nmp_ThrottleLogForDevice:3842: last error status from device naa.xxxxxxxxxxxxxxxxxx repeated 20 timesYYYY-MM-DDTXX:XX:XX.XXX In(182) vmkernel: cpu52:2097363)NMP: nmp_ThrottleLogForDevice:3893: Cmd 0xa3 (0x45da7ed50200, 0) to dev "naa.xxxxxxxxxxxxxxxxxx" on path "vmhba4:C0:T6:L0" Failed: YYYY-MM-DDTXX:XX:XX.XXX In(182) vmkernel: cpu2:2098591)NMP: nmp_ThrottleLogForDevice:3893: Cmd 0xf1 (0x45babab4d7c0, 25980411) to dev "naa.xxxxxxxxxxxxxxxxxx" on path "vmhba3:C0:T4:L0" Failed: YYYY-MM-DDTXX:XX:XX.XXX In(182) vmkernel: cpu8:2098585)ScsiDeviceIO: 4633: Cmd(0x45ba40f77080) 0xfe, CmdSN 0x663d34c2 from world 25980415 to dev "naa.xxxxxxxxxxxxxxxxxx" failed H:0x0 D:0x2 P:0x5 YYYY-MM-DDTXX:XX:XX.XXX In(182) vmkernel: cpu102:2098582)ScsiDeviceIO: 4633: Cmd(0x45da73dd2900) 0xfe, CmdSN 0x663d34c6 from world 25980408 to dev "naa.xxxxxxxxxxxxxxxxxx" failed H:0x0 D:0x2 P:0x5
……
YYYY-MM-DDTXX:XX:XX.XXX Wa(180) vmkwarning: cpu46:2098568)WARNING: ScsiDeviceIO: 1780: Device naa.xxxxxxxxxxxxxxxxxx performance has deteriorated. I/O latency increased from average value of 2117 microseconds to 62825 microseconds.
YYYY-MM-DDTXX:XX:XX.XXX Wa(180) vmkwarning: cpu46:2098568)WARNING: ScsiDeviceIO: 1780: Device naa.xxxxxxxxxxxxxxxxxx performance has deteriorated. I/O latency increased from average value of 2117 microseconds to 62825 microseconds.YYYY-MM-DDTXX:XX:XX.XXX Wa(180) vmkwarning: cpu46:2098574)WARNING: ScsiDeviceIO: 1780: Device naa.xxxxxxxxxxxxxxxxxx performance has deteriorated. I/O latency increased from average value of 2118 microseconds to 60798 microseconds.
vSphere vCenter Server 8.x
Devices are reporting high latency, causing virtual machines to become unresponsive during I/O operations.
Contact the storage vendor to fix the storage performance degradation issue.
For example, the performance of some EMC storage systems can significantly decrease when there is insufficient available space.