#PF Exception 14 in world #####:HELPER_MISC_ IP 0x############ addr 0x############PTEs:0x############;0x############;0x0;...0x############:[0x############]fnic_rq_clean@(nfnic)#<None>+0xcf stack: 0x############0x############:[0x############]cleanup_queue@(nfnic)#<None>+0x70 stack: 0x50x############:[0x############]fnic_detach@(nfnic)#<None>+0x28a stack: 0x############VMware vSphere ESXi 7.x
This issue is caused by fnic_rq_cleanup routine.
Engage your driver vendor.
Release Notes for Cisco UCS Virtual Interface Card Drivers, Release 6.0
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/release/notes/VIC/6-0/b-release-notes-for-cisco-ucs-vic-drivers-rel-6-0.html#id_125870mrel
|
Defect ID |
Description |
First Bundle Affected |
Resolved In |
|---|---|---|---|
|
CSCwk78247 |
The ESXi host encounters a PSOD error during fnic_rq_cleanup routine. This issue was seen on the following NFNIC driver versions:
This issue is now resolved in the NFNIC driver version 5.0.0.46. |
NFNIC driver version 5.0.0.40 |