You have created one or more profiles in Infrastructure Manager (View->Manage Profiles) and are experiencing one or more of the following symptoms:
hub: Profile - (profile name) ## bytes (INVAL)
DX UIM - 23.4.6 or prior
hub 23.4.6 or prior
The process that synchronizes the profiles can get stuck in a situation where two hubs are asking each other for the same profile but neither one of them has it, causing an infinite loop.
As a workaround, restart each hub that doesn't have the profile, and wait a few hours. Normally after one or more restarts, the profiles will eventually synchronize - in hub 23.4.6 and prior this can take approximately 3 hours.
If the profiles have not synchronized after 3 hours, restart the hub(s) again.