Bulk Migration Switchover failed with an error: "Can not poweroff vm as tools not available/not running and forcePoweroff is not set."
search cancel

Bulk Migration Switchover failed with an error: "Can not poweroff vm as tools not available/not running and forcePoweroff is not set."

book

Article ID: 419494

calendar_today

Updated On:

Products

VMware HCX

Issue/Introduction

  • Bulk Migration switchover failed with the following error:
    Can not poweroff vm as tools not available/not running and forcePoweroff is not set.

Environment

VMware HCX

Cause

During the HCX bulk migration, the source VM will be shut down, and this operation can fail for the following reasons. 

  • VMware Tools is not installed or running on the guest OS, or the VM is unresponsive.

  • The ESXi host managing the virtual machine became disconnected/unresponsive during the operation.

Resolution

  • Ensure VMware tools are installed and running on the guest OS.

  • Recover and reconnect the host to vCenter and retry the migration.

Additional Information

If you need assistance with the Host dioconnection issue, refer to Troubleshooting an ESXi host in a "not responding"/"disconnected" state, or open a support case with Broadcom Support. For more information, see Creating and managing Broadcom support cases.