WARNING: Uplink: Queue 0 of device vmnic# stuck, resetting the device
nenic: enic_uplink_reset: Resetting
nenic: enic_dev_log_qerror_capable: CMD_QUEUE_ERROR not supported
vob.net.uplink.watchdog.timeout: Watchdog timeout occurred for uplink vmnic#
VMware vSphere ESXi
In the UCS Manager vNIC template: Uncheck the no support failover option (This option can cause unwanted vNIC remapping and unstable vmnic ordering.)
After making changes, reboot the blade to apply the updated profile.
Enabling CDN ensures predictable vmnic enumeration during boot.
Cisco documentation describes how to enable CDN in BIOS policy: Cisco UCS Manager Server Management Guide