14:09:13.89233[1] PktHandleID: QBmXINxFAAA=, Captured at PktFree point, Drop Reason 'VlanTag Mismatch'. Drop Function 'VSwitchLookup'. TSO not enabled, RSS type 2 hash 1689173329, Checksum not offloaded and not verified, SourcePort 2214592528, headroomlen 208, length 102.
2025-08-28T12:58:10.724Z cpu153:2098754)icen: icen_SetPfDvm:1531: 0000:1f:00.1: Network adapter is configured in Single VLAN Mode2025-08-28T12:58:12.312Z cpu153:2098754)icen: icen_SetPfDvm:1531: 0000:45:00.1: Network adapter is configured in Double VLAN Mode
2025-08-28T12:58:10.998Z cpu183:2098788)WARNING: icen: icen_PrintHealthStatus:752: 0000:1f:00.1: DDP package failed2025-08-28T12:58:10.998Z cpu183:2098788)WARNING: icen: icen_PrintHealthStatus:753: 0000:1f:00.1: Possible Solution: Update to latest base driver and DDP package
VMware NSX
VMware vSphere ESXI
If a custom or the embedded DDP (Dynamic Device Personalization) package fails to load, the vmnic driver may default to single VLAN mode.
This is a condition that may occur in a VMware NSX environment.
Workaround:
Reboot the host to reload the NIC driver. In some circumstances it may be required to reinstall the driver.