Error: ESXi host powers off unexpectedly via ACPI signal
search cancel

Error: ESXi host powers off unexpectedly via ACPI signal

book

Article ID: 417985

calendar_today

Updated On:

Products

VMware vSphere ESXi

Issue/Introduction

  • ESXi host becomes unresponsive.
  • The host enters a powered-off state.
  • The following messages are observed in /var/run/log/hostd.log and vobd.log in the ESX Host:

    The host is being powered off through Advanced Configuration and Power Interface (ACPI). User: UNKNOWN_USER.

  • The following entry is found in /var/run/log/vmkernel.log in the ESX Host:

    VMKAcpi: 305: Power button pressed; requesting graceful shutdown and power off

  • A "soft-off" event is recorded in the IPMI System Event Log (SEL):

    Record Id: #### When: [TIMESTAMP] Event Type: 111 (Unknown) SEL Type: 2 (System Event) Message: Assert + System ACPI Power State S4/S5: soft-off Sensor Number: ####

Environment

  • VMware vSphere ESXi 7.x
  • VMware vSphere ESXi 8.x
  • VMware vSphere ESX 9.x

Cause

The ESXi kernel receives a hardware-layer ACPI shutdown signal. This signal originates outside of the vSphere software stack and is typically triggered by a physical power button press or a command from the Out-of-Band (OOB) management controller (e.g., iLO, iDRAC, and XCC.)

Resolution

  1. Review the Out-of-Band (OOB) management logs (iLO/iDRAC/CIMC) for the exact timestamp of the shutdown to identify the source of the ACPI signal.
  2. Audit physical access to the server chassis to rule out manual intervention.
  3. If the trigger source cannot be identified, contact the server hardware vendor to perform diagnostic tests on the server.

Additional Information

For more information, refer to Unexpected ESXi Reboot or Shutdown