Can I use LOADLIB parameter on CAS9 RIMPARM setting for CA InterTest batch r9.1?
search cancel

Can I use LOADLIB parameter on CAS9 RIMPARM setting for CA InterTest batch r9.1?

book

Article ID: 41695

calendar_today

Updated On:

Products

InterTest - CICS InterTest - Batch

Issue/Introduction

Question:

Can I use LOADLIB parameter on CAS9 RIMPARM setting for CA InterTest batch r9.1?

 

Answer:

CA InterTest Batch install guide stated as follow:

You must customize the CAIRIM procedure (CAS9). For detailed information, see the CA Common Services Administration Guide. Change STEPLIB and RIMPARM as follows:

STEPLIB

  The CAIRIM load library. If CA InterTest Batch was installed into a different target load library than CAIRIM, you must add the CA InterTest Batch CAMRLOAD data set to the STEPLIB concatenation. The CAMRLOAD data set must be APF authorized.

RIMPARM

 Add the following control card to the member or data set pointed to by the RIMPARM DD for initialization of CA InterTest Batch:

 PRODUCT(CA InterTest Batch) VERSION(MR91) INIT(MR91INIT) PARM(220)

 

If CAMRLOAD library is APF authorized then instead place on STEPLIB of CAS9 job, can be use LOADLIB(HLQ.CAMRLOAD) paramter on RIMPARM statement. 

 PRODUCT(CA InterTest Batch) VERSION(MR91) INIT(MR91INIT) PARM(220) LOADLIB(HLQ.CAMRLOAD)

This can be prevent CAS9 job to fail if CAMRLOAD library was not APF authorized or missing when CAMRLOAD library is in STEPLIB.

However if LOADLIB parameter used, instead of CAS9 job to fail, it only CA InterTest Batch INIT routine to fail.

 

Additional Information:

Reference CA InterTest Batch r9.1 Install guide.

 

Environment

Release: OSINBV00200-9.1-InterTest-Batch
Component: