HCX NE-HA group state "DEGRADED" with "ACTIVE/UNDECIDED"
search cancel

HCX NE-HA group state "DEGRADED" with "ACTIVE/UNDECIDED"

book

Article ID: 416906

calendar_today

Updated On:

Products

VMware HCX

Issue/Introduction

  • HCX NE pair shows UNDECIDED for standby appliances.


  • All the network extensions are functioning properly, and no issues with data paths observed.
  • HCX NE tunnel status for both NE's in HA pair are "UP".
  • The issue began when both NE pairs were mistakenly moved to the wrong cluster and later returned to the correct one.
  • After being moved to the wrong cluster, both NE tunnels went "DOWN" but came "UP" once they were restored to the correct cluster.
  • This left the NE-HA pair in a "DEGRADED" state with the status "ACTIVE/UNDECIDED".
  • A redeployment of the NE-HA Management was attempted, but it failed with the error: "Failed to verify cleanup of appliance backup records."

Environment

VMware HCX

Cause

The HCX NE-HA solution is unable to handle double fault scenarios and cannot recover if both the Active and Standby are down.

Resolution

In the current state of HCX NE-HA, please perform a REDEPLOY [Choose-Force] for the NE in the HA pair.

Additional Information

Manage Service Mesh Appliances

Managing Network Extension High Availability