Local Datastore Configured for Scratch Partition Appears Inaccessible in vCenter
book
Article ID: 416741
calendar_today
Updated On:
Products
VMware vSphere ESXi
Environment
VMware vSphere ESXi 7.x
VMware vSphere ESXi 8.x
Cause
The local datastore became inaccessible due to underlying hardware issues.
Cause validation:
- The iLO interface reports "No drives were found in this system. You may need to reboot the host system to discover them".

- The ESXi host relies on ILO for hardware status. As ILO failed to detect the drives, the datastores were marked inaccessible.
Resolution
- Reboot the host from iLO to bring back the drives as suggested by iLO.
- Engage the hardware vendor to investigate the root cause of the missing drives on iLO and assist with a permanent resolution.
Feedback
thumb_up
Yes
thumb_down
No