Missing data from NSX - Logical Port Operational Status error in Logs for VCF Operations for Networks
search cancel

Missing data from NSX - Logical Port Operational Status error in Logs for VCF Operations for Networks

book

Article ID: 416331

calendar_today

Updated On:

Products

VCF Operations for Networks

Issue/Introduction

VCF Operations for Networks missing data from NSX - Logical Port Operational Status error in Logs which indicates that the operational status cannot always be displayed for NSX logical port.

You see the error "Error in obtaining LogicalPortOperationalStatus for manager" in the Collector logs for your NSX data source as in the following example:

2025-10-24T13:04:58.815Z ERROR common.utils.CommonUtils NSXT_########.#####.###_Config_OpMgr-4 logException:2680 Error in obtaining LogicalPortOperationalStatus for manager https://########.#####.###:443 java.util.ConcurrentModificationException: null at java.util.ArrayList.forEach(ArrayList.java:1513) _[_:_] 

{redacted for space and clarity}

 

Environment

Aria Operations for Networks 6.13.0
Aria Operations for Networks 6.14.0
Aria Operations for Networks 6.14.1

Cause

Logical port operational status polling task hits this issue intermittently when two threads are concurrently trying to iterate and delete in the same cache respectively. 

Resolution

This issue is resolved in Aria Operations for Networks 6.14.2.

If you believe you have have encountered this issue: 

  1. Open a support case with Broadcom Support mentioning this KB number to review your VCF Operations for Networks deployment. For more information, see Creating and managing Broadcom support cases. 
  2. Generate support bundle for Aria Operations for Networks collector from GUI, see steps mentioned in KB