Double entry created for net connect in inventory
search cancel

Double entry created for net connect in inventory

book

Article ID: 415982

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

After probe version updated for net_connect probe 4.01 we can see double entry for single IP address in inventory.

Environment

UIM 23.4.4

Previous version of net_connect probe is 3.44

net_connect configured via MCS on group level

Metric QOS graph for net_connect is showing for the new entry in inventory.

net_connect probe is installed on hub and monitoring other robots under that hub 

Resolution

Deployed net_connect probe version 4.01T1 on the hub robot.

Deleted the existing MCS profiles and removed duplicate/dummy entries from the inventory. 
New MCS profiles were recreated at the group level, and observed that devices are now populating correctly in the inventory with proper metric data mapping.

 

net_connect probe version 4.01T1 test fix is attached to this KB

The changes will be included in the upcoming net_connect probe release 

Attachments

net_connect-4.01-T1-20251022.171223-4.zip get_app