vCenter reports "Path redundancy to storage device" alerts.
search cancel

vCenter reports "Path redundancy to storage device" alerts.

book

Article ID: 415882

calendar_today

Updated On:

Products

VMware vSphere ESXi

Issue/Introduction

Symptoms : 

  • Navigate to Affected host > monitor > events. vCenter will report "Path redundancy to storage device" alerts.
  • The /var/run/log/vobd.log file on the affected host confirms "Path redundancy to storage device" errors:
    YYYY-MM-DDTHH:MM.SSSZ In(14) vobd[2097956]:  [scsiCorrelator] 6266390031764us: [esx.problem.storage.redundancy.degraded] Path redundancy to storage device naa.################################ degraded. Path vmhba65:C0:T0:L382 is down. Affected datastores: Unknown.
    YYYY-MM-DDTHH:MM.SSSZ In(14) vobd[2097956]:  The event ([esx.problem.storage.redundancy.degraded] Path redundancy to storage device naa.################################ degraded. Path vmhba65:C0:T0:L382 is down. Affected datastores: Unknown.) was sent immediately to hostd;



 

Environment

VMware vSphere ESXi 7.x
VMware vSphere ESXi 8.x

Cause

Storage devices are unmapped from the array.

Cause validation:

  • The /var/run/log/vmkernel.log file on the affected host reports that the storage device was unmapped from the array. 
    2025-10-18T09:49:24.152Z Wa(180) vmkwarning: cpu52:3089024)WARNING: NMP: vmk_NmpSatpIssueTUR:1143: Device naa.################################ path vmhba65:C0:T0:L382 has been unmapped from the array
    2025-10-18T09:49:24.152Z Wa(180) vmkwarning: cpu52:3089024)WARNING: NMP: vmk_NmpSatpIssueTUR:1143: Device naa.################################ path vmhba65:C0:T1:L382 has been unmapped from the array
    2025-10-18T09:49:24.152Z Wa(180) vmkwarning: cpu52:3089024)WARNING: NMP: vmk_NmpSatpIssueTUR:1143: Device naa.################################ path vmhba3:C0:T1:L382 has been unmapped from the array
    2025-10-18T09:49:24.152Z Wa(180) vmkwarning: cpu52:3089024)WARNING: NMP: vmk_NmpSatpIssueTUR:1143: Device naa.################################ path vmhba3:C0:T0:L382 has been unmapped from the array

Resolution

Involve the storage vendor to further check on why the storage devices were unmapped and take necessary actions accordingly.