This article addresses the 'Error in configuring VLAN backed transport node collections' failure occurring during inventory synchronization in VMware Cloud Foundation (VCF) 9.x. This typically occurs when the synchronization task incorrectly initiates NSX transport node preparation on VLAN-backed clusters.
Inventory synchronization logic in VCF 9.x performs strict infrastructure validation and may inadvertently auto-align NSX state for detected clusters. This leads to the unintended application of NSX network filters and host configurations on non-NSX clusters
Before applying below steps, verify that all vSAN hosts have been decommissioned correctly. Residual metadata from unremoved disk groups or stale unicast agent entries often mimics this sync failure. Refer to KB Permanently Decommissioning a node from a vSAN Cluster for proper decommissioning procedures
Green' (NSX solution successfully applied).