Moving an ESXi host between domains requires decommissioning in VMware Cloud Foundation
search cancel

Moving an ESXi host between domains requires decommissioning in VMware Cloud Foundation

book

Article ID: 414650

calendar_today

Updated On:

Products

VMware SDDC Manager / VCF Installer VCF Operations

Issue/Introduction

In VMware Cloud Foundation (VCF) environments, administrators may require restructuring or consolidation of clusters within the management domain/workload domain.

A common request involves moving an ESXi host from a workload domain to the management domain or vice versa to achieve a single-cluster configuration.

The question arises whether this host migration can be performed directly, without executing a full decommissioning and recommissioning process through SDDC Manager.

Environment

VMware Cloud Foundation 5.x
VMware Cloud Foundation 9.x

Cause

In VCF, moving a host from a workload domain to the management domain is not supported through SDDC Manager.

This limitation exists because:

  • SDDC Manager tightly manages inventory, configuration, and lifecycle operations for all components within the domain, including clusters and hosts.

  • Each cluster is treated as an independent logical entity. Moving a host outside of the supported decommissioning workflow can lead to configuration drift or management inconsistencies.

  • Integrated services such as NSX-T, vSAN, and vSphere profiles are closely associated with the host’s original cluster context. Manual host relocation can disrupt these integrations and result in an unsupported state of the environment.

Resolution

If there is a requirement to reuse a host in a different workload domain, the host must be decommissioned, re-imaged, and commissioned before it is added to the workload domain.

To perform a cluster consolidation while maintaining supportability and operational stability, follow the supported workflow below:

  1. Decommission the ESXi Host
    1. In the navigation pane, click Inventory > Hosts
    2. Click Unassigned Hosts
    3. In the hosts table, select the host(s) to decommission.
    4. Click Decommission Selected Hosts.
    5. Activate or deactivate Skip failed hosts during decommissioning.
    6. Click Confirm.

      For more detailed information and prerequisites, refer to Decommission ESX Hosts

  1. Re-image the decommissioned host before commissioning it again and adding it to a workload domain.

  2. Commission the ESXi Host
    1. In the navigation pane, click Inventory > Hosts.
    2. Click Commission Hosts.
    3. On the Checklist page, review the prerequisites and confirm by clicking Select All.
    4. Click Proceed.
    5. Add host one at a time or import multiple hosts at once from a JSON file.
    6. Verify that the server fingerprint is correct for each host and then activate the Confirm All Fingerprints toggle.
    7. Click Validate All.
    8. Click Next.
    9. Activate or deactivate Skip failed hosts during commissioning.
    10. Click Commission.

For more detailed information and prerequisites, refer to Commission ESX Hosts

Additional Information

Following the supported decommission and recommission workflow ensures that SDDC Manager maintains complete visibility and control of all components in the environment.

This prevents lifecycle management disruptions and preserves integration consistency across NSX-T, vSAN, and vSphere services.

For detailed procedural guidance, refer to the official VMware documentation:
Remove a Host from a vSphere Cluster in a Workload Domain