NSX Edge TEP tunnels show as DOWN when bridging is enabled
search cancel

NSX Edge TEP tunnels show as DOWN when bridging is enabled

book

Article ID: 414269

calendar_today

Updated On:

Products

VMware NSX

Issue/Introduction

Environment

  • VMware NSX-T 3.x
  • VMware NSX 4.x

Cause

This issue occurs when ESXi compute transport nodes TEPs and Edge VMs are in the same subnet.

For tunnels between an Edge VM and its outer ESX compute transport nodes, BFD packets sent from the ESXi node will be delivered to the Edge VM without encapsulation, and the Edge VM drops the BFD packets without encapsulation.

For tunnels between an Edge VM and an ESX node which is not the host of certain Edge VM, BFD packets sent from the ESXi node is dropped by the ESXi node hosting the Edge VM because these packets are not destined to the local TEPs of the ESXi node hosting the Edge VM.

Resolution

When bridging is used, the ESXi TEPs must use a separate IP range/subnet from the NSX Edge nodes.

Please see KB 317168 - NSX-T Edge TEP networking options and page 325 of the NSX design guide for further details.