Unable to store device access event when CSP agent is registered with DCS 6.10 Management Server GA build
book
Article ID: 413983
calendar_today
Updated On:
Products
Data Center Security Server Advanced
Critical System Protection
Embedded Security Critical System Protection
Issue/Introduction
The customer reported an issue where the device access event could not be written to the CSPEvent table.
Error:
Data Error(s) in Event record - Invalid Event Type (PDEV)
Environment
- CSP Agent 8.0.x
- CSP Prevention Policy with Device Access rules enabled
- DCS 6.10 GA Management Server
Cause
This is a known issue for CSP agent that is managed by DCS 6.10 Management Server GA build.
Resolution
To resolve the issue, please upgrade the DCS Management Server, Communication Server and Console components to version 6.10 U1.
Feedback
thumb_up
Yes
thumb_down
No