Abend: MODULE=CNZC1SUB+00005B8C,ABEND=S0077 starting Opera
search cancel

Abend: MODULE=CNZC1SUB+00005B8C,ABEND=S0077 starting Opera

book

Article ID: 41388

calendar_today

Updated On:

Products

Opera

Issue/Introduction

Starting up Opera:
 
CAIW767I Interface for CASCHED Action not Available                    
CAIW769I Interface for CASEVEN Action is Available                     
CAIW350I CA-Opera Product Interface Active                             
CAIW651I CA-Opera Timer Component Active                               
CNZ0001I CNZC1SUB: SERVICE CNZC1OBU FAILED WITH RC:       4 RS:     402
...
DUMP TITLE=COMPON=CNZ,COMPID=SC1CK,ISSUER=CNZMIREC, 
MODULE=CNZC1SUB+00005B8C,ABEND=S0077,REASON=010E0A36
CAIW325I CA-Opera Subsystem Console 000 Obtained    
CAIW300I CA-Opera Subsystem Console Component Active
CAIW600I CA-Opera LOG Component Active              
CAIW430I CA-Opera CA-7 Interface Active             
CAWU100I CA-Opera Initial Startup Complete          
CAWU000I Console Automation is Active               
CAIW000I CA-Opera Subsystem Active    

              
 Opera still seems to run properly.
 


Environment

Release: 3.1

Resolution

This is usually caused by mishandling of the SYSZCNZ enqueue. If you are using GRS or  MIM and they are handling the SYSZCNZ enqueue then all
consoles MUST have UNIQUE names between LPARS. 
 
If you have GRS and  MIM you can update these products to NOT handle the enqueue for SYSZCNZ and this will allow NON-UNIQUE console names to exists between LPARS.