Starting up Opera:
CAIW767I Interface for CASCHED Action not Available
CAIW769I Interface for CASEVEN Action is Available
CAIW350I CA-Opera Product Interface Active
CAIW651I CA-Opera Timer Component Active
CNZ0001I CNZC1SUB: SERVICE CNZC1OBU FAILED WITH RC: 4 RS: 402
...
DUMP TITLE=COMPON=CNZ,COMPID=SC1CK,ISSUER=CNZMIREC,
MODULE=CNZC1SUB+00005B8C,ABEND=S0077,REASON=010E0A36
CAIW325I CA-Opera Subsystem Console 000 Obtained
CAIW300I CA-Opera Subsystem Console Component Active
CAIW600I CA-Opera LOG Component Active
CAIW430I CA-Opera CA-7 Interface Active
CAWU100I CA-Opera Initial Startup Complete
CAWU000I Console Automation is Active
CAIW000I CA-Opera Subsystem Active
Opera still seems to run properly.
Release: 3.1
This is usually caused by mishandling of the SYSZCNZ enqueue. If you are using GRS or MIM and they are handling the SYSZCNZ enqueue then all
consoles MUST have UNIQUE names between LPARS.