免責事項:これは英文の記事「Cannot hot add CBRC (digest) disks to non-CBRC VMs in vSphere 8.0 Update 3, "CBRC cannot be hot-enabled on a disk..."」の日本語訳です。記事はベストエフォートで翻訳を進めているため、ローカライズ化コンテンツは最新情報ではない可能性があります。最新情報は英語版の記事で参照してください。
CBRC cannot be hot-enabled on a disk unless the VM was powered-on with digest disks or cbrc.cache Enable was set
Unable to hot add source disk <disk_name>.vmdk, failing over to network mode
<timestamps> In(166) Hostd[2102278]: [Originator@6876 sub=Vmsvc.vm:/vmfs/volumes/<datastore>/<backup_proxy_or_app_VM_folder>/<backup_proxy_or_app_VM_name>.vmx opID=#### sid=### user=vpxuser:<domain>/<user>] Reconfigure failed: N3Vim5Fault20GenericVmConfigFault9ExceptionE(Fault cause: vim.fault.GenericVmConfigFault
<timestamps> In(166) Hostd[2102236]: --> )
<timestamps> In(166) Hostd[2102236]: --> [context]zKq7AVICAgAAAKckdwEWaG9zdGQAAOPJR2xpYnZtYWNvcmUuc28AgU+BHQFsaWJ2aW0tdHlwZXMuc28AAWF26IKpShEBaG9zdGQAgt4iDAGCHDUMAYKlPgwBAqdU/AKNffwCx4b8AqyN/AIKc/gCOkP5Ar9R+QJlVPmBMAoWAQK1lWIAHtssAOD/LAA7UFIDUngAbGlicHRocmVhZC5zby4wAAQ/Ug9saWJjLnNvLjYA[/context]
<timestamps> Wa(164) Hostd[2102278]: [Originator@6876 sub=Vmsvc.vm:/vmfs/volumes/<datastore>/<backup_proxy_or_app_VM_folder>/<backup_proxy_or_app_VM_name>.vmx opID=#### sid=### user=vpxuser:<domain>/<user>] Exception thrown during reconfigure: (vim.vm.ConfigSpec) {
<timestamps> Wa(164) Hostd[2102236]: --> createDate = "<timestamp>",
<timestamps> Wa(164) Hostd[2102236]: --> files = (vim.vm.FileInfo) {
<timestamps> Wa(164) Hostd[2102236]: --> vmPathName = "[]/vmfs/volumes/<datastore>/<backup_proxy_or_app_VM_folder>/<backup_proxy_or_app_VM_name>.vmx",
<timestamps> Wa(164) Hostd[2102236]: --> },
<timestamps> Wa(164) Hostd[2102236]: --> deviceChange = (vim.vm.device.VirtualDeviceSpec) [
<timestamps> Wa(164) Hostd[2102236]: --> (vim.vm.device.VirtualDeviceSpec) {
<timestamps> Wa(164) Hostd[2102236]: --> operation = "add",
<timestamps> Wa(164) Hostd[2102236]: --> device = (vim.vm.device.VirtualDisk) {
<timestamps> Wa(164) Hostd[2102236]: --> key = 0,
<timestamps> Wa(164) Hostd[2102236]: --> backing = (vim.vm.device.VirtualDisk.FlatVer2BackingInfo) {
<timestamps> Wa(164) Hostd[2102236]: --> fileName = "[]/vmfs/volumes/<datastore>/<backed_up_VM>/<VM_name>.vmdk",
<timestamps> Wa(164) Hostd[2102236]: --> diskMode = "independent_nonpersistent",
<timestamps> Wa(164) Hostd[2102236]: --> },
<timestamps> Wa(164) Hostd[2102236]: --> connectable = (vim.vm.device.VirtualDevice.ConnectInfo) {
<timestamps> Wa(164) Hostd[2102236]: --> startConnected = true,
<timestamps> Wa(164) Hostd[2102236]: --> allowGuestControl = false,
<timestamps> Wa(164) Hostd[2102236]: --> connected = true,
<timestamps> Wa(164) Hostd[2102236]: --> },
<timestamps> Wa(164) Hostd[2102236]: --> controllerKey = 1000,
<timestamps> Wa(164) Hostd[2102236]: --> unitNumber = 2,
<timestamps> Wa(164) Hostd[2102236]: --> capacityInKB = 0,
<timestamps> Wa(164) Hostd[2102236]: --> },
<timestamps> Wa(164) Hostd[2102236]: --> }
<timestamps> Wa(164) Hostd[2102236]: --> ],
<timestamps> Wa(164) Hostd[2102236]: --> }
<timestamps> Wa(164) Hostd[2102236]: --> N3Vim5Fault20GenericVmConfigFault9ExceptionE(Fault cause: vim.fault.GenericVmConfigFault
<timestamps> Wa(164) Hostd[2102236]: --> )
<timestamps> Wa(164) Hostd[2102236]: --> [context]zKq7AVICAgAAAKckdwEWaG9zdGQAAOPJR2xpYnZtYWNvcmUuc28AgU+BHQFsaWJ2aW0tdHlwZXMuc28AAWF26IKpShEBaG9zdGQAgt4iDAGCHDUMAYKlPgwBAqdU/AKNffwCx4b8AqyN/AIKc/gCOkP5Ar9R+QJlVPmBMAoWAQK1lWIAHtssAOD/LAA7UFIDUngAbGlicHRocmVhZC5zby4wAAQ/Ug9saWJjLnNvLjYA[/context]
VMware vSphere ESXi 8.0.3
vSphere 8.0 Update 3 では、CBRC の動作に変更が導入されました。
CBRC フィルターのメモリ消費量を削減するため、このバージョン以降、CBRC 対応(ダイジェスト)ディスクのホットアドは、対象の仮想マシンに既にダイジェストディスクが接続されている場合、または仮想マシンで CBRC が明示的に有効化されている場合にのみ許可されます。
この問題を解決するには、次の手順を適用してください:
cbrc.cacheEnable = "TRUE"