The following abend condition occurred in the Sysview Performance Management Option for DB2 for z/OS (IDB2) Data Collector.
Restart of the IDB2 Data Collector was normal but there was a brief interruption of service.
CSR010E NMSPRMVC S0C9 at 23EFF04C LMOD NSIGHTPR CSECT NDRITABC +00158C INDB2GDC INDB2G
CSR021IOWNER = SYSVIEW for DB2 R20.0
CSR022I MODULE = NDRITABC FMID = CIDBK00 RMID = LU14940
CSR060I BREAKING EVENT ADDRESS: 00000000 23EFEFDE
PSW: 07852000 80000000 00000000 23EFF04C
ILC: 04 INTERRUPT CODE: 09
COMPLETION CODE S0C9 REASON CODE 00000009
PTF LU16575 has been published to fix several problems and the S0C9 abend.
PTF LU16575 can be located at the following link:
ABEND S0C4 AFTER PROCESSING MORE THAN 2 BILLION RECORDS
The code correction for the S0C9 abend was included in the solution within the pre-requisite PTFs that have to be applied.