TMCC Abending with TMC00032E 'No records have been written and no apparent cause can be found'
search cancel

TMCC Abending with TMC00032E 'No records have been written and no apparent cause can be found'

book

Article ID: 413412

calendar_today

Updated On:

Products

MICS Resource Management

Issue/Introduction

TMC01000I COPYRIGHT (C) 2013 CA.  All Rights Reserved.
TMC00062I TMCC scan timestamp changed to 2025/255, 09:00:00 due to RMM header record.
TMC01010I RMMEARL Processing Statisics
TMC01010I ----------------------------
TMC01010I    Header Records : 1
TMC01010I    Extract Records: 0
TMC01010I    Other Records  : 2863830
TMC01010I    Total Records  : 2863831
TMC00025I 0 records written to TMCCOUT.
TMC90005I Ending collection for RMM.
TMC00032E No records have been written and no apparent cause can be found.
TMC00032E Please review the MICSLOG and JESLOG for additional information.
TMC99995E TMCC completed with errors. Return Code=4
TMC99998E TMCC is abending with U0998.

Resolution

For DFSMSrmm installations, the EDGHSKP utility must be run to extract data from the control data set (CDS).
DATEFORM(J) must be specified in the PARM= field. If any other value is used or if it is not specified, TMCC will reject the data. 
In addition, the XREPTEXT DD (Required) specifies the data set name for the EDGHSKP utility output.

 Ex.

// ... JOB ...
//EXTRACT  EXEC PGM=EDGHSKP,
//              PARM='DATEFORM(J) RPTEXT'
//SYSPRINT DD   SYSOUT=*
//MESSAGE  DD   SYSOUT=*
//XREPTEXT DD   DSN=extract.data.set.name,
//              DISP=(NEW,CATLG,DELETE),AVGREC=U,
//              SPACE=(CYL,(1000,500)),
//              UNIT=unit

 

Additional Information

Refer to TMCC JCL Samples