Network connectivity for VM is down for 30 seconds during failover of uplink.
book
Article ID: 413140
calendar_today
Updated On:
Products
VMware NSX
Issue/Introduction
Link aggregation control protocol is set for the VMs and vmkernels on the distributed switch , causing the network failover from one uplink to another taking around 30-60 seconds.
ESXi and Virtual machines losing network connectivity during the time of failover.
Shutting down one uplink is not immediately bringing down the interface on the switch end.
LACP is set to passive on the vCenter end and active on the physical network side.
From packet captures, we are noticing packets leaving the host immediately once the uplink goes but no response from the physical switch side
On the physical side, will see ethernet in suspended state.
Will notice below entry on the switch side:
Resolution
Workaround:
Set the LACP timeout mode to fast , PDUs are sent every second
Verify the reason for uplink not going down immediately on the physical switch side.