Why am I getting errors in CA OPS/MVS for the compiled version of the OPS/REXX program OP450000 when trying to access the OPSVIEW panel 4.5.1?
search cancel

Why am I getting errors in CA OPS/MVS for the compiled version of the OPS/REXX program OP450000 when trying to access the OPSVIEW panel 4.5.1?

book

Article ID: 41290

calendar_today

Updated On:

Products

OPS/MVS Event Management & Automation

Issue/Introduction

Issue: 

Why am I getting errors in CA OPS/MVS for the compiled version of the OPS/REXX program OP450000 when trying to access the OPSVIEW panel 4.5.1?

Symptoms:

When visiting OPSVIEW panel 4.5.1 "AOF Control" the following error messages could happen:

Invalid compiled OPS/REXX program - OP450000      
REBUILD FAILED FOR COMPILED REXX PROGRAM - OP450000

Resolution/Workaround:

This error usually occurs when the CA OPS/MVS library CCLXEXEC is allocated in the OPSEXEC DD concatenation of the TSO user session. The library that contains the compiled OPS/REXX programs is CCLXOPEX. The allocation of the CCLXOPEX library is optional but improves OPSVIEW performance.

Review the allocations of your TSO session and make sure the following relationship between DDNAMES and library names (DSNAMES) is correct:

DDNAME

DSNAME

Contents

SYSEXEC

prefix.CCLXEXEC

Source OPS/REXX programs (not compiled)

OPSEXEC

prefix.CCLXOPEX

Compiled OPS/REXX programs

 

Additional Information:

You can find additional information at our website: CA Technologies Documentation

Environment

Release: PVLA2.00200-12.2-OPS/MVS-Event Management & Automation-for JES2
Component: