We upgraded the WCC from 12.1.1 to 24.1.
There were no errors or warnings in the upgrade logs.
After the upgrade was completed, the WCC services would not start
We saw the following error in the collector.logINFO | jvm 1 | 2025/10/03 08:31:09 | 7 | @collector WrapperSimpleAppMain [] WARN #CPSubsystem #(265) []:7004 [MCTVDAwiZA] [4.2.8] CP Subsystem is not enabled. CP data structures will operate in UNSAFE mode! Please note that UNSAFE mode will not provide strong consistency guarantees.INFO | jvm 1 | 2025/10/03 08:31:11 | 8 | @collector WrapperSimpleAppMain [] ERROR #DefaultIntegrationService #(98) Lookup for Hazelcast instance from "java:comp/env/bean/clusterInstance" failed.INFO | jvm 1 | 2025/10/03 08:31:12 | 9 | Oct 03, 2025 8:31:12 AM com.ca.wcc.config.db.utils.JDBCUtils getReportingDBVersionINFO | jvm 1 | 2025/10/03 08:31:12 | 9 | INFO: Reporting database version is 12.0.01INFO | jvm 1 | 2025/10/03 08:31:12 | 9 | @collector WrapperSimpleAppMain [] ERROR #InitializationUtils #(211) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++INFO | jvm 1 | 2025/10/03 08:31:12 | 9 | @collector WrapperSimpleAppMain [] ERROR #InitializationUtils #(212) ++++++ ERROR ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++INFO | jvm 1 | 2025/10/03 08:31:12 | 9 | @collector WrapperSimpleAppMain [] ERROR #InitializationUtils #(213) Local version of REPORTING (24.0.01) is different than version of REPORTING in the db (24.0.01). INFO | jvm 1 | 2025/10/03 08:31:12 | 9 | @collector WrapperSimpleAppMain [] ERROR #InitializationUtils #(214) REPORTING will be stopped.
In the upgrade log we saw the following:2025-10-03 07:39:05,655 [Thread-24398] DEBUG com.ca.wla.ae.installer.customaction.initialize.AEDBSetUpgradeList(438) - isCollector ? false2025-10-03 07:39:05,655 [Thread-24398] DEBUG com.ca.wla.ae.installer.customaction.initialize.AEDBSetUpgradeList(442) - The database is at a lower level2025-10-03 07:39:05,655 [Thread-24398] DEBUG com.ca.autosys.db.connection.DBOperations(81) - Running query: SELECT PREFVALUE FROM CFG_GLOBAL_PREF WHERE PREFKEY=?2025-10-03 07:39:05,655 [Thread-24398] DEBUG com.ca.autosys.db.connection.DBOperations(191) - Query params:2025-10-03 07:39:05,655 [Thread-24398] DEBUG com.ca.autosys.db.connection.DBOperations(195) - [1 : internal.reporting.database.enabled]2025-10-03 07:39:05,655 [Thread-24398] DEBUG com.ca.autosys.db.validation.DBValidator(379) - DB_SETUP : isReportingDBenabled - null2025-10-03 07:39:05,655 [Thread-24398] DEBUG com.ca.wla.ae.installer.customaction.initialize.AEDBSetUpgradeList(471) - useReporting=false
AutoSys 24.X
The WCC database did not have a record of the Reporting being enabled.
Run the installer again, choosing to install the database schema and provide the database information and credentials for the WCC Reporting database