NSX Manager upgrade pre-check fails due to upgrade-coordinator processes are stuck
search cancel

NSX Manager upgrade pre-check fails due to upgrade-coordinator processes are stuck

book

Article ID: 412815

calendar_today

Updated On:

Products

VMware NSX

Issue/Introduction

  • Upgrade pre-check failed with the following message.
    Unexpected error while upgrading upgrade unit: NSX Manager upgrade dry run failed. Do not proceed with the upgrade. Please collect the support bundle and contact VMWare GS.
  • Retry pre-check also failed.
  • You see messages similar to following in /var/log/upgrade-coordinator/logical-migration.log on NSX Manager:
    ####-##-##T##:##:##.###Z ERROR main MVOCorfuCompileProxy 31741 Access[ImmutableCorfuTable[f2a]]
    org.corfudb.runtime.exceptions.TrimmedException: getStreamAddressMap[{f2a@-1}] [-1, ##########] stream has been trimmed at address ########## and this space is not covered by the loaded checkpoint with start address -1, while accessing the stream at version ##########. Looking for a new checkpoint.

Environment

VMware NSX

Cause

Resolution

  • This issue is fixed in VMware NSX 4.2.1.
  • Restart upgrade-coordinator service as admin on the NSX Manager where the pre-check invoked to unblock this situation.
    nsxmanager> restart service install-upgrade