The replication shows "Fail-Over" state on on the Incoming Replications view of the VMware Cloud Director Availability (VCDA) Portal for the affected replication.
The replication is still synchronizing and creating instances but the state is not correct.
The options to failover, test-failover and migrate are grayed.
Environment
VMware Cloud Director Availability 4.7.3
Cause
The cause for this issue is an inconsistency between the replicator and manager Data Bases caused by a failed replication task like Test-Failover, Failover or Migration.
Resolution
To resolve this problem reboot the Manager VM.
Log in to the management interface of the Manager Appliance:
In a Web browser, go to https://Appliance-IP-Address/ui/admin
Select Appliance login or SSO login and enter the root or the single sign-on user credentials. Click Login.
In the left pane, click System Health.
In the System health page, click Reboot VM.