Expanding a disk on a virtual machine fails with the error: A general system error occurred: PBM error occurred during PreReconfigureCallback: Fault cause: vmodl.fault.SystemError
book
Article ID: 411918
calendar_today
Updated On:
Products
VMware vCenter Server
Issue/Introduction
Symptoms:
Expanding a disk on a virtual machine fails with the error:
A general system error occurred: PBM error occurred during PreReconfigureCallback: Fault cause: vmodl.fault.SystemError
Environment
VMware vCenter Server 8.0.x
Cause
This error occurs when the Profile-Driven Storage service is not running or is not accepting connections.
Note: This service is also called Policy Based Management (PBM).
Resolution
To resolve the issue, ensure that the Profile-Driven Storage service is running.
SSH to the VCSA using PuTTY or similar SSH client.
Enter the shell of the vCSA. (If the prompt shows command> that is the appliance shell. The below commands cannot be ran in appliance shell.)
Run the following command to check the status of the service:
service-control --status vmware-sps
Run the following command to start the vmware-sps service: