It was asked if it is possible to allocate the trend log datasets with primary and secondary space values different from the default (14 tracks).
In the VKGPARMS member, within the product’s Parmlib dataset, the following parameters are defined:
TRENDPFX – prefix for Trend Log datasets
LOGDC – SMS data class for the Trend Log datasets
The SMS Data Class DCSAMS, specified in the LOGDC parameter, has the following values.
Override Space . . . . . : YES
Space Avgrec . . . . . . : K
Avg Value . . . . : 300
Primary . . . . . : 100
Secondary . . . . : 100
The Trend Log datasets are allocated with the DCSAMS data class, but the primary and secondary space values remain fixed at 14 tracks and this prevents the activation of ZEDC compression, since the minimum primary space required for ZEDC compression is 100 tracks.
This behavior is generated by the Management Class parameter
“Partial Release”
set to
CI (Cond Immed)
By changing this parameter to NO, the primary and secondary space remain unchanged, even after being overwritten by Vantage.
Check the link below for an explanation of the CI migration attribute of the Management Class :