brcontrol output) on initialization of the failover setup. resync_actions: <Date & Time>; Standby XML Import 'failover-standby-<Hostname>-<SAM Domain>.xml' (remote):
resync_actions: <Date & Time>; XML import of standby configuration into '<Hostname>:<Port>/<SAM Domain>' failed (remote), error: rc={65280}; ''
Smarts 10.1.X, 24.3.X
As per the review of the errors and functionality of Failover Manager, the error occurred during XML configuration import occurs when there is configuration mismatch between standby and active server, since during roles assignment configuration will be applied, if there is a mismatch in configuration, error will be thrown which is the case here. However in logs it is unsure why the mismatch would have happened, in ideal scenario if configurations are correct then the roles would have assigned properly.
Once the roles goes to UNKNOWN state, there is a need to restart SAM domains and failover domain both in order to fix the roles even if the configuration files have been copied.
If the configurations are setup correctly, and Active SAM domain managers are registered on the broker correctly, yet the roles show UNKNOWN, please report to Broadcom Support for further assistance.