Xmanager started task fails to start with ABEND S052 U0000 REASON=00000102
book
Article ID: 411373
calendar_today
Updated On:
Products
DATABASE MANAGEMENT SOLUTIONS FOR DB2 FOR Z/OSDatabase Management for DB2 for z/OS - Utilities SuiteDatabase Management for DB2 for z/OS - Recovery SuiteDatabase Management for DB2 for z/OS - Performance SuiteDatabase Management for DB2 for z/OS - Administration SuiteDatabase Management Suite for Db2Detector for DB2 for z/OS
Issue/Introduction
After applying Database Management Solutions for Db2 for z/OS maintenance the Xmanager STC fails to start with abend code:
The Xmanager STC was configured with two different un-synced CDBALOAD libraries in the STEPLIB and PTILIB DD statements, meaning they were either at different maintenance levels or not matching.
Resolution
Update the STEPLIB and PTILIB DD statements to use the same CDBALOAD. This should resolve the mismatch problem causing Xmanager not to start.