Disk Group and Device Latency seen on all ESXi hosts of the vSAN Cluster at the same time
search cancel

Disk Group and Device Latency seen on all ESXi hosts of the vSAN Cluster at the same time

book

Article ID: 410945

calendar_today

Updated On:

Products

VMware vSAN

Issue/Introduction

Symptoms:

  • Nearly all device groups on all ESXi hosts in a vSAN cluster show latency at the same time:

  • All cache devices and/or capacity devices of nearly all ESXi hosts in the vSAN cluster also show latency at the same time:

  • The ESXI hosts are part of the same Dell RAC server

Environment

  • VMware vSAN 8.x
  • VMware vSAN 9.x
  • Dell RAC servers

Cause

  • The issue is caused due to automatic firmware update of the SAS RAID firmware and the  PCIe SSD
  • The latency remains until the update gets over
  • The LC logs from Dell contain the below events:

<Event AgentID="iDRAC" Category="Updates" Severity="Informational" Timestamp="2025-07-07T10:10:36+0000" Sequence="2048">
    <Message>Downloading the FOLDER09232098M_3_SAS-RAID_Firmware_TTR5R_WN64_2.5.13.4009_A01_02.EXE update package.</Message>
    <MessageID>RED110</MessageID>
    <FQDD>N/A</FQDD>
    <MessageArgs>
      <Arg>FOLDER09232098M_3_SAS-RAID_Firmware_TTR5R_WN64_2.5.13.4009_A01_02.EXE</Arg>
    </MessageArgs>
    <RawEventData/>
    <Comment/>
    <Source/>
    <JobID/>
</Event>


<Event AgentID="iDRAC" Category="Updates" Severity="Informational" Timestamp="2025-07-07T10:11:27+0000" Sequence="2062">
  <Message>Downloading the FOLDER11088065M_1_Express-Flash-PCIe-SSD_Firmware_GR859_WN64_3.1.6_A05.EXE update package.</Message>
  <MessageID>RED110</MessageID>
  <FQDD>N/A</FQDD>
  <MessageArgs>
    <Arg>FOLDER11088065M_1_Express-Flash-PCIe-SSD_Firmware_GR859_WN64_3.1.6_A05.EXE</Arg>
  </MessageArgs>
  <RawEventData/>
  <Comment/>
  <Source/>
  <JobID/>
</Event>

Resolution

  • This is an issue with the lifecycle management of Dell devices.
  • Please contact Dell for further investigations and fix