snmpwalk ran against NSX Managers and NSX Edges responds with an unexpected node OID
search cancel

snmpwalk ran against NSX Managers and NSX Edges responds with an unexpected node OID

book

Article ID: 410719

calendar_today

Updated On:

Products

VMware NSX

Issue/Introduction

  • Running snmpwalk against an NSX Manager or Edge returns a node OID belonging to a different node type. 
    • The following sample is from snmpwalk ran against an NSX Edge. 

snmpwalk -v 2c -c public 192.###.###.10

.1.3.6.1.2.1.1.2.0 = OID: 1.3.6.1.4.1.6876.4.131\
.1.3.6.1.2.1.1.3.0 = TIMETICKS: 352287608\
.1.3.6.1.2.1.1.4.0 = STRING: ""\
.1.3.6.1.2.1.1.5.0 = STRING: "NSXEDGE01"\

  • In the VMWARE-PRODUCTS-MIB we can see the OID 1.3.6.1.4.1.6876.4.131 aligns with vmwNSXManagerAppliance rather than the expected vmwNSXEdgeAppliance. 

VMWARE-PRODUCTS-MIB             vmwNSXEdgeAppliance                                               node         1.3.6.1.4.1.6876.4.130
VMWARE-PRODUCTS-MIB             vmwNSXManagerAppliance                                            node         1.3.6.1.4.1.6876.4.131

Environment

VMware NSX 4.x

VMware NSX-T Data Center 3.x

Resolution

This is a cosmetic issue only and doesn't affect primary SNMP functionality. 

Starting in VCF 9, both NSX Managers and NSX Edges will respond with OID 1.3.6.1.4.1.6876.4.6 which aligns with vmwGenericAppliance.