NVMe over TCP datastores are lost after ESXi upgrade
book
Article ID: 410234
calendar_today
Updated On:
Products
VMware vCenter Server
VMware vSphere ESX 8.x
VMware vSphere ESXi
Issue/Introduction
NVMe over TCP datastores are missing after performing an ESXi upgrade
Environment
VMware vSphere ESXi 8.x
VMware vCenter Server 8.x
Cause
Missing Storage IP and port details for Storage NQN within NVME over TCP vmhba adapter.
Resolution
Check or compare another working host for NVMe over TCP vmhba adapter to the missing datastore and copy the storage controller details.
- Check controller details in NVMe over TCP vmhba adapter:

- Check for target/storage controller details:

- Copy storage controller details from working host and add in non-working host in NVMe over TCP adapter for controller details.
- Manually add or repopulate the missing storage IP and port details within NVMe over TCP adapter for controller details.

- Once completed, perform adapter rescan & storage rescan to detect devices/volumes.
Additional Information
https://www.vmware.com/docs/configuring-nvmeof-tcp