An error occurred during host configuration: . Operation failed, diagnostics report: Unable to create Filesystem, please see VMkernel log for more details: Failed to create VMFS on device "VMware vSphere ESXi 7.x
VMware vSphere ESXi 8.x
Commands timing out to the Storage lun which triggers the HBA to abort I/O's causing the datastore creation to fail.
vmkernel logs of the ESXi host, while creating the datastore write(2a) command issued to the storage lun fail with the scsi sense code (H:0x8 D:0x0 P:0x0) :2025-08-28T10:18:32.382Z In(182) vmkernel: cpu46:2098458)qlnativefc: vmhba3(b0:0.0): qlnativefcStatusEntry:2067:C0:T10:L7 - FCP command status: 0x5-0x0 (0x8) portid=020a01 oxid=0x325 cdb=2a0000 len=131072 rspInfo=0x0 resid=0x0 fwResid=0x0 host status = 0x8 device status $2025-08-28T10:18:32.382Z In(182) vmkernel: cpu66:2097732)qlnativefc: vmhba3(b0:0.0): qlnativefcEhAbort:2746:qlnativefcEhAbort: abortCommand mbx success.2025-08-28T10:18:32.382Z In(182) vmkernel: cpu66:2097732)qlnativefc: vmhba3(b0:0.0): qlnativefcEhAbort:2774:C0:T11:L7: Abort command succeeded -- 12025-08-28T10:18:32.382Z In(182) vmkernel: cpu46:2098425)NMP: nmp_ThrottleLogForDevice:3864: Cmd 0x2a (0x45da8307e4c0, 2100155) to dev "naa.##########################" on path "vmhba3:C0:T10:L7" Failed:2025-08-28T10:18:32.382Z In(182) vmkernel: cpu46:2098425)NMP: nmp_ThrottleLogForDevice:3869: H:0x8 D:0x0 P:0x0 . Act:EVAL. cmdId.initiator=0x430b0faf3880 CmdSN 0x172025-08-28T10:18:32.382Z Wa(180) vmkwarning: cpu46:2098425)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:235: NMP device "naa.##########################" state in doubt; requested fast path state update...2025-08-28T10:18:32.382Z In(182) vmkernel: cpu46:2098425)ScsiDeviceIO: 4605: Cmd(0x45da8307e4c0) 0x2a, CmdSN 0x17 from world 2100155 to dev "naa.##########################" failed H:0x8 D:0x0 P:0x02025-08-28T10:18:32.382Z Wa(180) vmkwarning: cpu57:2100247 opID=fcfb0429)WARNING: HBX: 3035: Write error: Timeout2025-08-28T10:18:32.382Z Wa(180) vmkwarning: cpu57:2100247 opID=fcfb0429)WARNING: Vol3: 1702: Error initializing heartbeat region: Timeout2025-08-28T10:18:32.383Z In(182) vmkernel: cpu57:2100247 opID=fcfb0429)FSS: 2408: Failed to create FS on dev [########-########-####-############] fs type [vmfs6] fbSize 1048576 => Timeout
This status is returned when the HBA driver has aborted the I/O. It can also occur if the HBA does a reset of the target.
Link : VMware ESXi SCSI Sense Code Decoder
Read (0x28) failing with the same scsi sense code (H:0x8 D:0x0 P:0x0) returned from the array.
Engage the storage/fabric vendor to investigate connectivity issues to the storage LUNs by checking switch logs for errors, validating zoning and path setup, and reviewing storage array configuration for the luns.