Issue/Introduction

The IDMS dc-log (OLP) is flooded with messages such as:

DC128010 V1 T100 CEE3611I The run-time option VERSION was an invalid run-time option or is not
DC128010 V1 T100          supported in this release of Language Environment.
DC128010 V1 T100 CEE3627I The following messages pertain to the programmer default run-time options.
DC128010 V1 T100 CEE3611I The run-time option LIBRARY was an invalid run-time option or is not
DC128010 V1 T100          supported in this release of Language Environment.
DC128010 V1 T100 CEE3611I The run-time option RTLS was an invalid run-time option or is not supported
DC128010 V1 T100          in this release of Language Environment.
DC128010 V1 T100 CEE3611I The run-time option VERSION was an invalid run-time option or is not
DC128010 V1 T100          supported in this release of Language Environment.
DC128010 V1 T100 CEE3627I The following messages pertain to the programmer default run-time options.
DC128010 V1 T100 CEE3611I The run-time option LIBRARY was an invalid run-time option or is not

Environment

Release: All supported releases.

Cause

The messages are coming from LE runtime and indicate that the CV is running with CEEUOPT options that are obsolete with respect to the current LE runtime environment.

Resolution

Re-link the IDMS CV's RHDCLEFE/CEEUOPT modules with more up-to-date options as described at Re-link RHDCLEFE.

However, the fact that the CV is issuing these messages is an indication that the CV might be using an obsolete IDMS method for specifying the CEEUOPT values. It is highly recommended that all IDMS clients use the RHDCLEFE method. See Runtime Options at Considerations for IBM Language Environment.

Additional Information