esxcli storage san fc list" on the ESXi host displays the Port State of the affected HBAs in down state as highlighted below: Adapter: vmhba4 Port ID: 000000 Node Name: 20:00:#:#:#:#:#:#:#:#:# Port Name: 21:00::#:#:#:#:#:#:#:#:# Speed: 0 Gbps Port Type: LPort Port State: LINK DOWN Model Description: QLE2692 Dual Port 16Gb FC to PCIe Gen3 x8 Adapter Hardware Version: OptionROM Version: 3.62 Firmware Version: 9.10.11 (d0d5) Driver Name: qlnativefc DriverVersion: 5.3.80.0VMware vSphere ESXi 7.x
The issue could be due to a hardware problem with the Fibre Channel (FC) Host Bus Adapter (HBA) or a connectivity issue between the FC HBA and the connected FC switch port.
/var/log/vmkernel.log file of the ESXi host points to FC HBA connectivity issue with the FC fabric:2025-10-02T12:25:30.567Z In(182) vmkernel: cpu38:2097964)qlnativefc: vmhba1(13:0.0): qlnativefcTimer:10013:Cable is unplugged.2025-10-02T12:25:32.567Z In(182) vmkernel: cpu46:2097964)qlnativefc: vmhba2(13:0.1): qlnativefcTimer:10013:Cable is unplugged.
Engage the hardware vendor to perform a complete diagnostic of the FC HBA and verify link stability. If the issue still persists then involve the FC Fabric vendor to inspect the FC switch port, cable, and SFP for any physical or optical issues.
Additionally, verify the HBA compatibility with the ESXi version and ensure the HBA firmware and driver are up-to-date and supported.
To validate the driver and firmware version running on the Host Bus Adapters (HBA) refer to this article: Determining Network/Storage firmware and driver version in ESXi