During HCX OSAM Migration showing error Initial Sync Failed SDR Error (Enabling replica storage failed)
search cancel

During HCX OSAM Migration showing error Initial Sync Failed SDR Error (Enabling replica storage failed)

book

Article ID: 408967

calendar_today

Updated On:

Products

VMware HCX

Issue/Introduction

  • OSAM migration fails during Initial Sync with error:

SDR Error (Enabling replica storage failed)

  • On the SDR/SRG appliance /var/log/messages  you see:
<date> <SRG-Name> sdrd 1939 - - [Err-sdr-replStor] : freshPartTable: failed, exit status 1
STDERR:
partx: specified range <1:0> does not make sense

<date> <SRG-Name> sdrd 1939 - - [Err-sdr-wdr] : [####-###-###-####] : Error in enabling storage : Verify storage failed : exit status 1
<date> <SRG-Name> sdrd 1939 - - [Err-sdr-rcm] : Verify storage failed : exit status 1%!(EXTRA *rcmError.RcmError=&{1007 Verify storage failed : exit status 1})
<date> <SRG-Name> sdrd 1939 - - [Err-sdr-rcm] : [####-###-###-####] : Transitioning to ERROR state : &{1007 Verify storage failed : exit status 1}

 

Cause

Source Machine has a disk in offline status

Resolution

Only NTFS formatted volumes are supported.

Additional Information