Logical Switch Status may incorrectly show as FAILED with no impact to realization
book
Article ID: 408556
calendar_today
Updated On:
Products
VMware NSXVMware vSphere ESXi
Issue/Introduction
Logical Switches seen in Manager mode show as Operational status: Fail
Policy mode shows the segment as successful and there are no reports of any network connectivity issues.
Newly created Logical Switches have no issues and show correct status in Policy/Manager Mode
When using this command as root in NSX Manager #corfu_tool_runner.py -n nsx -t LogicalSwitchState -o showTable > LSS.txt, all the associated VDS PortGroup are in SUCCESS state.
Environment
VMware NSX 4.2.0
Resolution
This is a known issue impacting VMware NSX 4.2.0 and is fixed in NSX 4.2.1
Workaround
Go to the Segment/LogicalSwitch with this issue on Manager UI and edit the Segment/LogicalSwitch to update the Description field (see screenshot attached for reference).
You can just added a whitespace at the end and remove it and save the Segment.
This should cause the LS state to turn into IN_PROGRESS and fix the "stateStatus" field to CONFIG_STATUS_SUCCESS.