Aria operations for Networks (AON) UI shows no flows on the NSX Data source
book
Article ID: 408524
calendar_today
Updated On:
Products
VCF Operations for Networks
Issue/Introduction
From AON UI -> Settings -> Data source, you are not seeing any flows:
On the NSX Manager UI -> Plan & Troubleshoot -> IPFIX -> Collectors, you confirmed that the collector is added.
Environment
Aria Operations for Networks
VCF Operations for Networks
Cause
The NSX Manager was added with a user permission different from the "enterprise_admin, network_engineer, or security_engineer" roles, which is required for IPFIX.
Resolution
Change the user role permissions on the NSX Manager UI -> System ->User Management -> User Role Assignment to following permissions "enterprise_admin, network_engineer, or security_engineer".
Edit the NSX-T data source on the AON UI, ensure the collector profile selected is correct, add the User with required permission and 'Save' the configuration.
Toggle OFF the data collection and wait for some time and toggle ON.
The flows should start to populate the environment (reference image below):