ALERT: Some images may not load properly within the Knowledge Base Article. If you see a broken image, please right-click and select 'Open image in a new tab'. We apologize for this inconvenience.

When starting the XNET started task why is it failing with the error message: xntTCP900E Listener error: PXNWTSS function LISTEN - 13: Access denied.

book

Article ID: 4084

calendar_today

Updated On:

Products

Bind Analyzer for DB2 for z/OS SQL-Ease for DB2 for z/OS SYSVIEW Performance Management Option for DB2 for z/OS Plan Analyzer for DB2 for z/OS Subsystem Analyzer for DB2 for z/OS

Issue/Introduction

The XNET started task fails upon startup with the error: xntTCP900E Listener error: PXNWTSS function LISTEN - 13: Access denied. 

Cause

The listener error -13 (Access Denied) will occur if PORT UNRSV TCP * DENY WHENLISTEN is stated in the TCPIP profile, but the port associated with the XNET STC 

has not been reserved for its use.

Environment

Release:
Component: CIDB

Resolution

Reserve the PORT (as stated in the XNET STC proc) for XNET's use.