A job submitted from system SYSA with Jobtrac token A to a system SYSB with token B runs with success but its status remains as NAWT at the origin node.
Jobtrac
The token of the submitting system (A) was missing in the list of tokens accepted by SYSB.
1) Visit the panel SYS OPTS on the destination system.
2) Choose 1 Global options
3) Include the token of the submitting node (A in this example) in the list of NJE Node Tokens:
NJE Node (Y/N) => Y
NJE Node Tokens => BA <--- here
A similar error may occur if the systems are not connected via Goalnet.