OM Deliver MAKECKPT function returns the following error :-
MAKECKPT CYLINDER=100 VOLSER=VOLUME1
RMOCPP02 CHECKPOINT PHYSICAL I/O ERROR - ECB=42000000
The Deliver Checkpoint file allocation was being changed from Cylinders to tracks
Disable the Deliver Database and Checkpoint files from products like ALLOC Dasd Space and Placement
The Deliver allocation in this case was being changed from cylinders to tracks which is not allowed for the Deliver files.