VMware vSphere ESXi 7.0.x
This can be caused by the storage array target rejecting PLOGI request from the initiator (HBA).
2025-07-30T15:28:46.751Z cpu24:2097893)nfnic: <2>: INFO: fdls_process_tgt_plogi_rsp: 1726: PLOGI returned FC_LS_REJ from target: 0xcf0a80
2025-07-30T15:28:46.751Z cpu24:2097893)nfnic: <2>: INFO: fnic_tport_exch_reset: 4896: Tport exch reset: target id: 2 tport->fcid: 0xcf0a80
Engage the storage and fabric vendors to investigate and address potential LUN visibility or configuration issues on the storage array and associated fabric paths to the ESXi hosts.
Additionally, verify the HBA compatibility with the ESXi version and ensure the HBA firmware and driver are up-to-date and supported.
To validate the driver and firmware version running on the Host Bus Adapters (HBA) refer to this article: Determining Network/Storage firmware and driver version in ESXi